Electrolyzed hydrogen water intake
Connect the tap water supply hose to the faucet to draw out electrolyzed hydrogen water/acidic water/purified water from the protruding swivel faucet on top of the apparatus. The swivel faucet spins 360 degrees, allowing you to add water to a variety of containers.
The micro-carbon cartridge is made from a porous carbon material containing countless micropores on its interior. The cartridge quickly absorbs dissolved solids while thoroughly removing particles that cause turbidity. Thanks to a new construction, the micro carbon alone can now remove 13 substances designated under Japanese Industrial Standards as well as 6 substances designated under the Japan Water Purifier Association's own standards. The filter material is also recognized for its anti-clogging and exceptional flow properties.
1. Non-woven fabric
The porous sheet is made from a combination of fibers layered into a 3D construction. This layer removes large particles before they pass through the micro-carbon.
2. Micro-carbon (extremely fine activated coal)
Nihon Trim's micro-carbon cartridge uses NSF-certified activated carbon (developed in collaboration with Nihon Trim).
[NSF-certified activated carbon manufacturer/Part no.]
- Kuraray Co., Ltd./T-SCO 60/150THM
- Futamura Chemical Co., Ltd./CN8200G
NSF International is a globally recognized nonprofit organization engaged in the protection of public health. The strict standards it enacts as part of its public health protection must be met before receiving NSF certification.
*Test results based on Japan Water Purifier Association's in-house standards and testing methods according to JIS S 3201 (filter test flow rate of 4L)
13 substances specified in the JIS standard | |||
---|---|---|---|
1 | Free Residual Chlorine (calcium hypochlorite) | 8 | Tetrachloroethylene |
2 | Turbidity | 9 | Trichloroethylene |
3 | Total Trihalomethane* | 10 | 1,1,1-trichloroethane |
4 | Chloroform | 11 | CAT (agrichemical) |
5 | Bromodichloromethane | 12 | 2-MIB (mold smell) |
6 | Dibromochloromethane | 13 | Soluble Lead |
7 | Bromoform |
6 substances specified in the Japan Water Purifier Association Independent Standard | |||
---|---|---|---|
1 | Geosmin (mold smell) | 4 | Carbon Tetrachloride |
2 | Phenols | 5 | Benzene |
3 | Anionic Surfactants | 6 | Cis-1,2-dichloroethylene and Trans-1,2-dichloroethylene |
The filtering capacity of TRIM ION TI-9000 is around 12t. Water flow is calculated via an integrated flowmeter. Once a year has passed since first use or the total amount of water filtered reaches 12t, you will be notified by a buzzer and blinking light.
Powering up the electrolytic voltage allows for generating EHW from an expanded range of typically hard-to-electrolyze sources, including raw water and well water.
To achieve more efficient electrolysis, it is necessary to increase the overall electrical load per unit volume of water. TRIM ION TI-9000 utilizes an 8-cell multi-layer electrolyzer to increase electrolyzing performance.
The large operation panel allows for easy manipulation.
The large touch switch has been treated with a waterproof embossment to protect against water splashback from the sink.
A melody accompanied by 10 blue LED lights will signal when electrolyzed hydrogen water is being generated. For those sensitive to noise, the volume can be adjusted according to your preference.
This valve allows for adjusting the intake balance between drainage water and electrolyzed hydrogen water. Adjusting the drainage volume also lets you control the electrolyzed hydrogen water's concentration.
A set of 7 types of adapters allows for easy attachment on all standard types of faucets.
Electrolyzing tap water that is rich in electrolytes may cause an abnormal surge in electric current. To prevent this, TRIM ION TI-9000 is equipped with a device to stabilize the flow of electricity.
Overheating has been known to occur in regions with electrolyte-rich tap water. TRIM ION TI-9000 is paired with a minimum flow recirculation system to prevent the apparatus from overheating and ensure its continued safe operation.
This safety feature activates the apparatus's protective circuits in the event of an indirect lightning strike.
Model number | TRIM ION TI-9000EX |
---|---|
Medical Equipment Production and Sale Certification Number | 21500BZZ00119000 |
Rated voltage | 200-240V AC |
Rated frequency | 50/60 Hz |
Rated current | 3A (max 5A) |
Rated electrolytic voltage | DC70V(max) |
Power consumption | 300W (max 500W) |
Electrolytic baths | 4 baths (8 cells) |
Electrodes (number of plates) | Platinum-tick coated titanium electrode (5 plates) |
Electrode durability time | 4,000 hours as an electrolyte (Varies with usage conditions such as amount used and water quality, etc.) |
Generated water intake system | one-way type |
Rated intake of electrolyzed hydrogen water | Approx. 5.0L/min (max) |
Rated intake of acidic water | Approx. 5.0L/min (max) |
Rated intake of purified water | Approx. 6.0L/min (max) |
Hydraulic pressure of piping system | 50kPa (minimum operational water pressure) up to 700kPa |
Electric cord length | 2m |
Weight | 5kg |
Size | 271(W)×367(H)×138(D) mm |
Lactic acid calcium adding device | Addition through case insertion (Lactic acid calcium is an auxiliary material added to facilitate electrolysis) |
Cartridge filtration capacity | 13 substances designated by JIS (*1) 12t (removal rate of over 80%) Test results based on JIS S 3201 (filter test flow rate 4L/m) 6 substances designated by Japan Water Purifier Association's in-house standards (*2) 12t (removal rate of over 80%) Test results based on Japan Water Purifier Association's in-house standards (filter test flow rate 4L/m) (Lasts for approximately 1 year when used at a rate of 32L/day. Results may vary according to volume, quality, and pressure of the water during use.)
|
Electrolyzer washing method | Double, Auto-changing, Crossline method |
Power supply circuit | Switching Regulator Control System |
Protective functions | Fuse (built-in substrate): 8A Constant current control circuit (overcurrent prevention device) Minimum flow recirculation system Branch faucet constant flow valve Branch faucet warning valve (excessive water pressure prevention) Twin safety valve function (hot water/excessive water pressure prevention) |